BJO

HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
[Advanced]

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Read responses to this article
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this link to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Feltgen, N.
Right arrow Articles by Funk, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Feltgen, N.
Right arrow Articles by Funk, J.
Br J Ophthalmol 2001;85:85-87 ( January )

Scientific correspondence

Correlation between central corneal thickness, applanation tonometry, and direct intracameral IOP readings Nicolas Feltgen, Dorothee Leifert, Jens Funk

Department of Ophthalmology, Albert-Ludwigs- University Freiburg, Germany

Correspondence to: Dr med Nicolas Feltgen, Universitäts-Augenklinik, Killianstrasse 5, 79106 Freiburg, Germany feltgen{at}aug.ukl.uni-freiburg.de

Accepted for publication 27 July 2000

BACKGROUND---Several authors reported incorrect high intraocular pressure (IOP) values in eyes with a thick cornea using applanation tonometry. This hypothesis was checked by comparing applanation tonometry with direct intracameral manometry.
METHODS---73 patients, scheduled for intraocular surgery, were enrolled. Immediately before surgery, the following were registered: (i) central corneal thickness (CCT), (ii) applanatory IOP (Perkins/Tonopen), and (iii) intracameral IOP.
RESULTS---The difference between applanatory and intraocular measurements was completely independent of CCT (y=-3.43+3.8x; where y is the difference between applanatory and intracamerally measured IOP (mm Hg) and x is CCT (mm); r2=0.002; p=0.72).
CONCLUSIONS---There is no systematic error of applanation tonometry with increasing CCT. Therefore it is inadequate to recalculate IOP based on regression formula of applanatory IOP versus CCT.


© 2001 by British Journal of Ophthalmology



This article has been cited by other articles:


Home page
Br. J. Ophthalmol.Home page
A R Ismail, M Lamont, S Perera, D Khan-Lim, R Mehta, J D A Macleod, and D F Anderson
Comparison of IOP measurement using GAT and DCT in patients with penetrating keratoplasties
Br. J. Ophthalmol., July 1, 2007; 91(7): 980 - 981.
[Full Text] [PDF]


Home page
Arch OphthalmolHome page
M. C. Grieshaber, A. Schoetzau, C. Zawinka, J. Flammer, and S. Orgul
Effect of Central Corneal Thickness on Dynamic Contour Tonometry and Goldmann Applanation Tonometry in Primary Open-angle Glaucoma
Arch Ophthalmol, June 1, 2007; 125(6): 740 - 744.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
C J W Hudson, L S Kim, S A Hancock, I A Cunliffe, and J M Wild
Some dissociating factors in the analysis of structural and functional progressive damage in open-angle glaucoma
Br. J. Ophthalmol., May 1, 2007; 91(5): 624 - 628.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
A. Kotecha, A. Elsheikh, C. R. Roberts, H. Zhu, and D. F. Garway-Heath
Corneal Thickness- and Age-Related Biomechanical Properties of the Cornea Measured with the Ocular Response Analyzer
Invest. Ophthalmol. Vis. Sci., December 1, 2006; 47(12): 5337 - 5347.
[Abstract] [Full Text] [PDF]


Home page
Arch OphthalmolHome page
M. Kohlhaas, A. G. Boehm, E. Spoerl, A. Pursten, H. J. Grein, and L. E. Pillunat
Effect of central corneal thickness, corneal curvature, and axial length on applanation tonometry.
Arch Ophthalmol, April 1, 2006; 124(4): 471 - 476.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
A Kotecha, E T White, J M Shewry, and D F Garway-Heath
The relative effects of corneal thickness and age on Goldmann applanation tonometry and dynamic contour tonometry
Br. J. Ophthalmol., December 1, 2005; 89(12): 1572 - 1575.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
P-A Tonnu, T Ho, T Newson, A El Sheikh, K Sharma, E White, C Bunce, and D Garway-Heath
The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry
Br. J. Ophthalmol., July 1, 2005; 89(7): 851 - 854.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
L. Tong, S.-M. Saw, J.-K. Siak, G. Gazzard, and D. Tan
Corneal Thickness Determination and Correlates in Singaporean Schoolchildren
Invest. Ophthalmol. Vis. Sci., November 1, 2004; 45(11): 4004 - 4009.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
C. Kaufmann, L. M. Bachmann, and M. A. Thiel
Comparison of Dynamic Contour Tonometry with Goldmann Applanation Tonometry
Invest. Ophthalmol. Vis. Sci., September 1, 2004; 45(9): 3118 - 3121.
[Abstract] [Full Text] [PDF]


Home page
Arch OphthalmolHome page
J. Li, L. W. Herndon, S. G. Asrani, S. Stinnett, and R. R. Allingham
Clinical Comparison of the Proview Eye Pressure Monitor With the Goldmann Applanation Tonometer and the TonoPen
Arch Ophthalmol, August 1, 2004; 122(8): 1117 - 1121.
[Abstract] [Full Text] [PDF]


Home page
Arch OphthalmolHome page
B. Nemesure, S.-Y. Wu, A. Hennis, and M. C. Leske
Association of Corneal Thickness and Intraocular Pressure--Reply
Arch Ophthalmol, March 1, 2004; 122(3): 425 - 426.
[Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
S Miglior, E Albe, M Guareschi, G Mandelli, S Gomarasca, and N Orzalesi
Intraobserver and interobserver reproducibility in the evaluation of ultrasonic pachymetry measurements of central corneal thickness
Br. J. Ophthalmol., February 1, 2004; 88(2): 174 - 177.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
C. Kaufmann, L. M. Bachmann, and M. A. Thiel
Intraocular Pressure Measurements Using Dynamic Contour Tonometry after Laser In Situ Keratomileusis
Invest. Ophthalmol. Vis. Sci., September 1, 2003; 44(9): 3790 - 3794.
[Abstract] [Full Text] [PDF]


Home page
Arch OphthalmolHome page
B. Nemesure, S.-Y. Wu, A. Hennis, M. C. Leske, and for the Barbados Eye Study Group
Corneal Thickness and Intraocular Pressure in the Barbados Eye Studies
Arch Ophthalmol, February 1, 2003; 121(2): 240 - 244.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
A. Bhan, A. C. Browning, S. Shah, R. Hamilton, D. Dave, and H. S. Dua
Effect of Corneal Thickness on Intraocular Pressure Measurements with the Pneumotonometer, Goldmann Applanation Tonometer, and Tono-Pen
Invest. Ophthalmol. Vis. Sci., May 1, 2002; 43(5): 1389 - 1392.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
R. Stodtmeister, M. Kron, W. Gaus, N. Feltgen, and J. Funk
IOP measurement and central corneal thickness
Br. J. Ophthalmol., January 1, 2002; 86(1): 120 - 121.
[Full Text] [PDF]

eLetters:

Read all eLetters

IOP measurement and central corneal thickness
Richard Stodtmeister, Martina Kron, Wilhelm Gaus
BJO Online, 15 Oct 2001 [Full text]
Re: IOP measurement and central corneal thickness - authors' reply
Nicolas Feltgen and Jens Funk
BJO Online, 15 Oct 2001 [Full text]



HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
Terms and conditions relating to subscriptions purchased online  ¦  Website terms and conditions  ¦  Privacy policy
Copyright © 2001 by the BMJ Publishing Group Ltd.