BJO

HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
[Advanced]

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this link to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Briscoe, D
Right arrow Articles by Biedner, B
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Briscoe, D
Right arrow Articles by Biedner, B
Br J Ophthalmol 1998;82:415-418 ( April )

A new computer program for mass screening of visual defects in preschool children

D Briscoe,a T Lifshitz,a M Grotman,b A Kushelevsky,b H Vardi,c S Weizman,c B Biednera

a Department of Ophthalmology, Soroka Medical Centre, Ben-Gurion University of the Negev, Beer-Sheba, Israel, b Optitest Ofakim, Ofakim, Israel, c Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheba, Israel

Correspondence to: B Biedner, MD, Department of Ophthalmology, Soroka Medical Centre, PO Box 151, Beer-Sheba, Israel.

Accepted for publication 5 November 1997

AIMS---To test the effectiveness of a PC computer program for detecting vision disorders which could be used by non-trained personnel, and to determine the prevalence of visual impairment in a sample population of preschool children in the city of Beer-Sheba, Israel.
METHODS---292 preschool children, aged 4-6 years, were examined in the kindergarten setting, using the computer system and "gold standard" tests. Visual acuity and stereopsis were tested and compared using Snellen type symbol charts and random dot stereograms respectively. The sensitivity, specificity, positive predictive value, negative predictive value, and kappa test were evaluated. A computer pseudo Worth four dot test was also performed but could not be compared with the standard Worth four dot test owing to the inability of many children to count.
RESULTS---Agreement between computer and gold standard tests was 83% and 97.3% for visual acuity and stereopsis respectively. The sensitivity of the computer stereogram was only 50%, but it had a specificity of 98.9%, whereas the sensitivity and specificity of the visual acuity test were 81.5% and 83% respectively. The positive predictive value of both tests was about 63%. 27.7% of children tested had a visual acuity of 6/12 or less and stereopsis was absent in 28% using standard tests. Impairment of fusion was found in 5% of children using the computer pseudo Worth four dot test.
CONCLUSIONS---The computer program was found to be stimulating, rapid, and easy to perform. The wide availability of computers in schools and at home allow it to be used as an additional screening tool by non-trained personnel, such as teachers and parents, but it is not a replacement for standard testing.

Keywords: screening; visual defects; amblyopia; computer program; stereopsis


© 1998 by British Journal of Ophthalmology



This article has been cited by other articles:


Home page
Arch OphthalmolHome page
A. Sharma, L. Li, Y. Song, K. Choi, D. S. C. Lam, M. Zhang, M. Zheng, Z. Zhou, X. Liu, B. Wu, et al.
Strategies to Improve the Accuracy of Vision Measurement by Teachers in Rural Chinese Secondary Schoolchildren: Xichang Pediatric Refractive Error Study (X-PRES) Report No. 6